Surge Arrester V50-4+FS-275, T1+T2, Uc 275VAC, impulse current (10/350μs) Iimp 12.5kA, discharge current (8/20μs)| Imax 60kA ^In 30kA, Up ≤1.8kV, tA ≤25ns, FS 0.5A 250VAC/ 3A 30VDC| 1.5mm2, 2.5..25mm², TN-S, TÜV, CB, CE, MaxPro
Image is illustrative
Surge Arrester V50-4+FS-275, T1+T2, Uc 275VAC, impulse current (10/350μs) Iimp 12.5kA, discharge current (8/20μs)| Imax 60kA ^In 30kA, Up ≤1.8kV, tA ≤25ns, FS 0.5A 250VAC/ 3A 30VDC| 1.5mm2, 2.5..25mm², TN-S, TÜV, CB, CE, MaxPro
Code: V50-4-FS-275
Price
€108.00  /pc
Manufacturer :
Availability:
In Stock
Weight:
0.6143 kg/pc
Volume:
0.0007 m3/pc
Quantity (pc):
Plus sign Minus sign
 


• Type 1+2 AC surge protection device
• Impulse/maximum discharge current [Iimp/Imax]: 12.5kA/60kA
• Varistor voltage limiting technology, low residual voltage design
• Pluggable design and internal thermal disconnection devices
• Operating/fault indication, optional remote signal
• Conform to IEC 61643-11,EN 61643-11,GB/T 18802.11

Technology Parameters
AC Working Voltage[ Un ]230VAC
Maximum Continuous Operating Voltage[ Uc ]275VAC
Temporary Overvoltage Test Value TOV-5s [Tolerance][ Ut ]335VAC
Temporary Overvoltage Test Value TOV-120min [Disconnection][ Ut ]440VAC
Nominal Discharge Current [8/20µs][ In ]30kA
Maximum Discharge Current [8/20µs][ Imax ]60kA
Impulse Discharge Current [10/350µs][ Iimp ]12.5kA
Voltage Protection Level[ Up ]≤1.8kV
Short-circuit Current Rating [backup SCB or FUSE][ Isccr ]25kA
Response Time[ tA ]≤25ns
Thermal Disconnection DeviceInsertion
Max. Backup Fuse160~200A gG fuse
Mechanical Data
Wiring MethodScrew terminal 2.5–25mm² [busbar can be used]
Normal/Fault DisplayGreen/Red
Remote SignalYes
Maximum Remote Signal Load Voltage/current0.5A 250VAC / 3A 30VDC
Maximum Cross-sectional Area Of Remote Signal Connection Line1.5mm²
Installation35mm DIN rail
Operating Temperature Range[ Tu ]-40..85°C
Protection LevelIP20
Enclosure MaterialThermoplastic materials, UL94-V0