Elit logo e-Elit - leading
electronic and automation component
online distributor
Est En
Elit shopping basket
Items: Total:
0
€0.00
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Enclosure ECOR, 400Wx600Hx200D, transparent door, mounting plate, 2locks w. ø3mm double bar key, AISI304L, IP66, NEMA12
Enclosure ECOR, 400Wx600Hx200D, transparent door, mounting plate, 2locks w. ø3mm double bar key, AISI304L, IP66, NEMA12



Simatic S7-1200, CPU 1212C, compact CPU, DC/DC/DC, onboard I/O: 8DI 24VDC, 6DO 24VDC, 2AI 0..10VDC, sv 20.4..28.8VDC, progr./data memory 75kB
Image is illustrative
Simatic S7-1200, CPU 1212C, compact CPU, DC/DC/DC, onboard I/O: 8DI 24VDC, 6DO 24VDC, 2AI 0..10VDC, sv 20.4..28.8VDC, progr./data memory 75kB
Code: 6ES7212-1AE40-0XB0
Price (indicative)
€230.42  /pc
Manufacturer :
Availability:
14 days
Weight:
0.357 kg/pc
Volume:
0.001 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Simatic S7-1200, CPU 1212C, compact CPU, DC/DC/DC, onboard I/O: 8DI 24VDC/ 6DO 24VDC/ 2AI 0..10VDC, 20.4..28.8VDC, program/data memory 75kB, Siemens

General information
Product type designation CPU 1212C DC/DC/DC
Engineering with
● Programming package STEP 7 V13 SP1 or higher
Supply voltage
Rated value (DC)
● 24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
Input current
Current consumption (rated value) 400 mA; Typical
Inrush current, max. 12 A; at 28.8 V DC
Output current
for backplane bus (5 V DC), max. 1 000 mA; Max. 5 V DC for SM and CM
Encoder supply
24 V encoder supply
● 24 V Permissible range: 20.4V to 28.8V
Power loss
Power loss, typ. 9 W
Memory
Work memory
● integrated 50 kbyte
● expandable No
Load memory
● integrated 1 Mbyte
● Plug-in (SIMATIC Memory Card), max. 2 Gbyte; with SIMATIC memory card
Backup
● present Yes; maintenance-free
● without battery Yes
CPU processing times
for bit operations, typ. 0.085 µs; / Operation
for word operations, typ. 1.7 µs; / Operation
for floating point arithmetic, typ. 2.3 µs; / Operation
CPU-blocks
Number of blocks (total) DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
OB
● Number, max. Limited only by RAM for code
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 10 kbyte
Flag
● Number, max. 4 kbyte; Size of bit memory address area
Address area
I/O address area
● Inputs 1 024 byte
● Outputs 1 024 byte
Process image
● Inputs, adjustable 1 kbyte
● Outputs, adjustable 1 kbyte
Hardware configuration
Number of modules per system, max. 3 comm. modules, 1 signal board, 2 signal modules
Time of day
Clock
● Hardware clock (real-time) Yes
● Backup time 480 h; Typical
● Deviation per day, max. ±60 s/month at 25 °C
Digital inputs
Number of digital inputs 8; Integrated
● of which inputs usable for technological functions 6; HSC (High Speed Counting)
Number of simultaneously controllable inputs
all mounting positions
— up to 40 °C, max. 8
Input voltage
● Rated value (DC) 24 V
● for signal "0" 5 V DC at 1 mA
● for signal "1" 15 V DC at 2.5 mA
Input current
● for signal "1", typ. 1 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms
— at "0" to "1", min. 0.1 µs
— at "0" to "1", max. 20 ms
for interrupt inputs
— parameterizable Yes
for counter/technological functions
— parameterizable Single phase: 3 @ 100 kHz & 1 @ 30 kHz, differential: 3 @ 80 kHz & 1 @ 30 kHz
Cable length
● shielded, max. 500 m; 50 m for technological functions
● unshielded, max. 300 m; For technological functions: No
Digital outputs
Number of digital outputs 6
● of which high-speed outputs 4; 100 kHz Pulse Train Output
Short-circuit protection No; to be provided externally
Limitation of inductive shutdown voltage to L+ (-48 V)
Switching capacity of the outputs
● with resistive load, max. 0.5 A
● on lamp load, max. 5 W
Output voltage
● for signal "0", max. 0.1 V; with 10 kOhm load
● for signal "1", min. 20 V
Output current
● for signal "1" rated value 0.5 A
● for signal "0" residual current, max. 0.1 mA
Output delay with resistive load
● "0" to "1", max. 1 µs
● "1" to "0", max. 3 µs
Cable length
● shielded, max. 500 m
● unshielded, max. 150 m
Analog inputs
Number of analog inputs 2
Input ranges
● Voltage Yes
Input ranges (rated values), voltages
● 0 to +10 V Yes
● Input resistance (0 to 10 V) ≥100k ohms
Cable length
● shielded, max. 100 m; twisted and shielded
Analog outputs
Number of analog outputs 0
Cable length
● shielded, max. 100 m; shielded, twisted pair
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 10 bit
● Integration time, parameterizable Yes
● Conversion time (per channel) 625 µs
Encoder
Connectable encoders
● 2-wire sensor Yes
1. Interface
Interface type PROFINET
Physics Ethernet
Isolated Yes
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Functionality
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
PROFINET IO Controller
Services
— Number of IO devices with prioritized startup, max. 16
Protocols
Supports protocol for PROFINET IO Yes
PROFIBUS Yes; CM 1243-5 required
AS-Interface Yes
Protocols (Ethernet)
● TCP/IP Yes
Open IE communication
● ISO-on-TCP (RFC1006) Yes
Further protocols
● MODBUS Yes
Communication functions
S7 communication
● supported Yes
● as server Yes
● as client Yes
Web server
● supported Yes
Test commissioning functions
Status/control
● Status/control variable Yes
Forcing
● Forcing Yes
Diagnostic buffer
● present Yes
Traces
● Number of configurable Traces 2; Up to 512 KB of data per trace are possible
Integrated Functions
Number of counters 6
Counting frequency (counter) max. 100 kHz
controlled positioning Yes
PID controller Yes
Number of alarm inputs 4
Number of pulse outputs 4
Limit frequency (pulse) 100 kHz
Potential separation
Potential separation digital inputs
● Potential separation digital inputs 500V AC for 1 minute
● between the channels, in groups of 1
Potential separation digital outputs
● Potential separation digital outputs 500V AC for 1 minute
● between the channels, in groups of 1
Permissible potential difference
between different circuits 500 V DC between 24 V DC and 5 V DC
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Yes
— Test voltage at air discharge 8 kV
— Test voltage at contact discharge 6 kV
Interference immunity to cable-borne interference
● Interference immunity on supply lines acc. to IEC 61000-4-4 Yes
● Interference immunity on signal cables acc. to IEC 61000-4-4 Yes
Interference immunity against voltage surge
● on the supply lines acc. to IEC 61000-4-5 Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Yes
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes; Group 1
● Limit class B, for use in residential areas Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
Degree and class of protection
Degree of protection acc. to EN 60529
● IP20 Yes
Standards, approvals, certificates
CE mark Yes
UL approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
Marine approval Yes
Ambient conditions
Free fall
● Fall height, max. 0.3 m; five times, in product package
Ambient temperature during operation
● min. -20 °C
● max. 60 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical
● horizontal installation, min. -20 °C
● horizontal installation, max. 60 °C
● vertical installation, min. -20 °C
● vertical installation, max. 50 °C
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Air pressure acc. to IEC 60068-2-13
● Operation, min. 795 hPa
● Operation, max. 1 080 hPa
● Storage/transport, min. 660 hPa
● Storage/transport, max. 1 080 hPa
Relative humidity
● Operation, max. 95 %; no condensation
Vibrations
● Operation, tested according to IEC 60068-2-6 Yes
Pollutant concentrations
● SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
Configuration
Programming
Programming language
— LAD Yes
— FBD Yes
— SCL Yes
Cycle time monitoring
● adjustable Yes
Dimensions
Width 90 mm
Height 100 mm
Depth 75 mm
last modified: 11/21/2017
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 