Elit logo e-Elit - leading
electronic and automation component
online distributor
Est En
Elit shopping basket
Items: Total:
0
€0.00
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Compact Cylinder ADN-50-25-A-P-A, 536314, Festo
Compact Cylinder ADN-50-25-A-P-A, 536314, Festo



Simatic DP, Electronic Module ET 200S, 4F-DO ProfiSafe, 2A 24VDC, W30mm, PL E, SIL3, ProfiNet w. IM151-3, Siemens
Image is illustrative
Simatic DP, Electronic Module ET 200S, 4F-DO ProfiSafe, 2A 24VDC, W30mm, PL E, SIL3, ProfiNet w. IM151-3, Siemens
Code: 6ES7138-4FB04-0AB0
Price (indicative)
€517.30  /pc
Manufacturer :
Availability:
21 days
Weight:
0.091 kg/pc
Volume:
0.0002 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Simatic DP, electronic module f. ET200S, 4 F-DO ProfiSafr, 2A 24VDC, W30mm, Pl e, SIL3, ProfiNet w. IM151-3, Siemens

Supply voltage
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection No
Input current
From load voltage L+ (no load), typ. 100 mA
from backplane bus 3.3 V DC, max. 28 mA
Power loss
Power loss, typ. 3.5 W
Digital outputs
Number of digital outputs 4
Short-circuit protection Yes
Limitation of inductive shutdown voltage to Typ. (2L+) -47 V
Controlling a digital input No
Switching capacity of the outputs
● on lamp load, max. 10 W
Load resistance range
● lower limit 12 Ω
● upper limit 1 kΩ
Output voltage
● for signal "1", min. L+ (-2,0 V), current sourcing switch: L+ (-1,5 V), voltage drop on current sinking switch: max. 0.5 V
Output current
● for signal "1" rated value 2 A
● for signal "1" permissible range, min. 20 mA
● for signal "1" permissible range, max. 2.4 A
● for signal "0" residual current, max. 0.5 mA; Current-sourcing and current-sinking switches
Parallel switching of two outputs
● for uprating No
● for redundant control of a load No
Switching frequency
● with resistive load, max. 30 Hz; Symmetrical
● with inductive load, max. 0.1 Hz; Symmetrical
● on lamp load, max. 10 Hz; Symmetrical
Total current of the outputs
● Current per module, max. 6 A
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max. 6 A
— up to 55 °C, max. 5 A
— up to 60 °C, max. 4 A
vertical installation
— up to 40 °C, max. 4 A
Cable length
● shielded, max. 500 m
● unshielded, max. 500 m
Interrupts/diagnostics/status information
Diagnostic functions Yes
Diagnostic messages
● Wire-break Yes
● Short-circuit Yes
Diagnostics indication LED
● Group error SF (red) Yes
● Status indicator digital output (green) Yes
Potential separation
Potential separation digital outputs
● between the channels No
● between the channels and backplane bus Yes
● Between the channels and load voltage L+ No
Isolation
tested with
● Load voltage L+ against backplane bus 2 545 V DC
Standards, approvals, certificates
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 PLe
● SIL acc. to IEC 61508 SIL 3
Dimensions
Width 30 mm
Height 81 mm
Depth 52 mm
Weights
Weight, approx. 85 g