Chassis Adapter ControlLogix, f. Redundant Power Supply, Rockwell Automation



Sitop PSU100S 20A, StabilizedPower Supply, 120/230VAC, 24V/20ADC, Siemens
Image is illustrative
Sitop PSU100S 20A, StabilizedPower Supply, 120/230VAC, 24V/20ADC, Siemens
Code: 6EP1336-2BA10
Price (indicative)
€253.20  /pc
Manufacturer :
Availability:
ask for dd
Weight:
2.52 kg/pc
Volume:
0.005 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Sitop PSU100S 20A, StabilizedPower Supply, 120/230VAC, 24V/20ADC, Siemens

SITOP PSU100S 24 V/20 A
SITOP PSU100S 20 A Stabilized power supply input: 120/230 V AC, output: 24 V DC/20 A
Input
Input 1-phase AC
● Note Automatic range selection
Supply voltage
● 1 at AC Rated value 120 V
● 2 at AC Rated value 230 V
Input voltage
● 1 at AC 85 ... 132 V
● 2 at AC 176 ... 264 V
Wide-range input No
Overvoltage resistance 2.3 × Vin rated, 1.3 ms
Mains buffering at Vin = 120/230 V
Mains buffering at Iout rated, min. 20 ms; at Vin = 120/230 V
Rated line frequency 1 50 Hz
Rated line frequency 2 60 Hz
Rated line range 47 ... 63 Hz
Input current
● at rated input voltage 120 V 7.5 A
● at rated input voltage 230 V 3.5 A
Switch-on current limiting (+25 °C), max. 11 A
I²t, max. 10 A²·s
Built-in incoming fuse T 10 A (not accessible)
Protection in the mains power input (IEC 898) Recommended miniature circuit breaker: from 10 A characteristic C or circuit-breaker 3RV2411-1JA10 (120 V) or 3RV2411-1FA10 (230 V)
Output
Output Controlled, isolated DC voltage
Rated voltage Vout DC 24 V
Total tolerance, static ± 3 %
Static mains compensation, approx. 0.5 %
Static load balancing, approx. 1 %
Residual ripple peak-peak, max. 150 mV
Spikes peak-peak, max. (bandwidth: 20 MHz) 240 mV
Adjustment range 24 ... 28 V
Product function Output voltage adjustable Yes
Output voltage setting via potentiometer; max. 480 W
Status display Green LED for 24 V OK
Signaling Relay contact (NO contact, rating 50 V DC/ 0.3 A) for "24 V OK"
On/off behavior No overshoot of Vout (soft start)
Startup delay, max. 1.5 s
Voltage rise, typ. 50 ms
Voltage increase time of the output voltage maximum 500 ms
Rated current value Iout rated 20 A
Current range 0 ... 20 A
● Note 24 A up to +45°C; +60 ... +70 °C: Derating 5%/K
Supplied active power typical 480 W
Short-term overload current
● on short-circuiting during the start-up typical 35 A
● at short-circuit during operation typical 35 A
Duration of overloading capability for excess current
● on short-circuiting during the start-up 100 ms
● at short-circuit during operation 100 ms
Parallel switching for enhanced performance Yes
Numbers of parallel switchable units for enhanced performance 2
Efficiency
Efficiency at Vout rated, Iout rated, approx. 90 %
Power loss at Vout rated, Iout rated, approx. 53 W
Closed-loop control
Dynamic mains compensation (Vin rated ±15 %), max. 1 %
Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ. 3 %
Setting time maximum 10 ms
Protection and monitoring
Output overvoltage protection Yes, according to EN 60950-1
Current limitation, typ. 21 A
Property of the output Short-circuit proof Yes
Short-circuit protection Electronic shutdown, automatic restart
Enduring short circuit current RMS value
● maximum 7 A
Overcurrent overload capability in normal operation overload capability 150 % Iout rated up to 5 s/min
Overload/short-circuit indicator -
Safety
Primary/secondary isolation Yes
Galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
Protection class Class I
Leakage current
● maximum 3.5 mA
● typical 1 mA
Degree of protection (EN 60529) IP20
Approvals
CE mark Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
Explosion protection IECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2, Group ABCD, T4
FM approval -
CB approval Yes
Marine approval DNV GL
EMC
Emitted interference EN 55022 Class B
Supply harmonics limitation EN 61000-3-2
Noise immunity EN 61000-6-2
environmental conditions
Ambient temperature
● during operation 0 ... 70 °C
— Note with natural convection
● during transport -40 ... +85 °C
● during storage -40 ... +85 °C
Humidity class according to EN 60721 Climate class 3K3, no condensation
Mechanics
Connection technology screw-type terminals
Connections
● Supply input L1, N, PE: 1 screw terminal each for 0.2 ... 4 mm² single-core/finely stranded
● Output +, -: 2 screw terminals each for 0.2 ... 4 mm²
● Auxiliary 13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm²
Width of the enclosure 115 mm
Height of the enclosure 145 mm
Depth of the enclosure 150 mm
Required spacing
● top 50 mm
● bottom 50 mm
● left 0 mm
● right 0 mm
Weight, approx. 2.4 kg
Product feature of the enclosure housing for side-by-side mounting Yes
Installation Snaps onto DIN rail EN 60715 35x7.5/15
Electrical accessories Buffer module
Mechanical accessories Device identification label 20 mm × 7 mm, pale turquoise 3RT1900-1SB20
MTBF at 40 °C 1 778 916 h
Other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 