Siplus SM 331, Analog Input Module, HART, 8AI 4..20mA, -25..70°C w. conf. coating, Siemens
Image is illustrative
Siplus SM 331, Analog Input Module, HART, 8AI 4..20mA, -25..70°C w. conf. coating, Siemens
Code: 6AG1331-7TF01-7AB0
Price (indicative)
€2,748.10  /pc
Manufacturer :
Availability:
ask for dd
Weight:
0.2625 kg/pc
Volume:
0.001 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Siplus SM 331, Analog Input Module, HART, 8AI 4..20mA, -25..70°C w. conf. coating, Siemens

SIPLUS SM 331 AI 8x0/4...20 mA -25...+70 °C with conformal coating based on 6ES7331-7TF01-0AB0
Supply voltage
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 20 mA
from backplane bus 5 V DC, max. 120 mA
Output voltage
Power supply to the transmitters
● Rated value (DC) 24 V
Power loss
Power loss, typ. 1.5 W
Analog inputs
Number of analog inputs 8
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
● Voltage No
● Current Yes
● Thermocouple No
● Resistance thermometer No
● Resistance No
Input ranges (rated values), currents
● 0 to 20 mA Yes
● Input resistance (0 to 20 mA) 240 Ω
● Input resistance (-20 mA to +20 mA) 240 Ω
● Input resistance (4 mA to 20 mA) 240 Ω
Cable length
● shielded, max. 800 m
Analog value generation for the inputs
Measurement principle Sigma Delta
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit
● Integration time, parameterizable Yes
● Integration time (ms) 20 ms at 50 Hz; 16.6 ms at 60 Hz; 100 ms at 100 Hz
● Interference voltage suppression for interference frequency f1 in Hz 10 / 50 / 60 Hz
Encoder
Connection of signal encoders
● for current measurement as 2-wire transducer Yes
● for current measurement as 4-wire transducer Yes
Errors/accuracies
Operational error limit in overall temperature range
● Current, relative to input range, (+/-) 0.15 %; ±0.25 % @ < 0 °C or > 60 °C
Basic error limit (operational limit at 25 °C)
● Current, relative to input range, (+/-) 0.1 %
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
● Limit value alarm Yes
Diagnostic messages
● Diagnostic information readable Yes
Diagnostics indication LED
● Group error SF (red) Yes
Potential separation
Potential separation analog inputs
● between the channels and backplane bus Yes
Isolation
Isolation tested with 500
Standards, approvals, certificates
CE mark Yes
UL approval Yes; File E239877
RCM (formerly C-TICK) Yes
KC approval Yes
EAC (formerly Gost-R) Yes
Railway application
● EN 50121-4 No
● EN 50155 No
Ambient conditions
Ambient temperature during operation
● min. -25 °C; = Tmin
● max. 70 °C; = Tmax; 60 °C @ UL/cUL use
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m
● Ambient air temperature-barometric pressure-altitude Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max. 100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3 Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3 Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3 Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6 Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6 Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6 Yes; Class 6S3 incl. sand, dust; *
Remark
— Note regarding classification of environmental conditions acc. to EN 60721 * The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086 Yes; Class 2 for high availability
● Military testing according to MIL-I-46058C, Amendment 7 Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A Yes; Conformal coating, Class A
Connection method
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 117 mm
Weights
Weight, approx. 205 g