|
|
|
Image is illustrative
|
Potential Distributor Terminal PTRVB 4-FI /GY, 10pcs/pck, Phoenix Code:
3270138
Price
€164.00
/pk
Package 10pc, unit price
16.4EUR/pc
Manufacturer
:
Availability:
21 days
|
Weight:
0.0213 kg/pc
|
Volume:
0.0001 m3/pc
|
|
|
|
|
Potential Distributor Terminal PTRVB 4-FI /GY, 10pcs/pck, PhoenixGeneral
Number of positions
|
2
|
Number of rows
|
4
|
Number of connections
|
13
|
Potentials
|
1
|
Nominal cross section
|
1.5 mm²
|
Nominal cross section feed-in
|
4 mm²
|
Color
|
gray
|
Color of connection elements
|
gray
|
Insulating material
|
PA
|
Flammability rating according to UL 94
|
V0
|
Mounting type
|
NS 35/7,5
|
Rated surge voltage
|
4 kV
|
Overvoltage category
|
III
|
Insulating material group
|
I
|
Maximum load current
|
24 A (per chamber with 2.5 mm² conductor cross section)
|
Maximum total current
|
37 A (per potential distributor)
|
Nominal current IN
|
17.5 A (with 1.5 mm² conductor cross section)
|
Nominal voltage UN
|
250 V
|
Maximum load current
|
37 A (Service Entrance)
|
Nominal current IN
|
32 A (Supply, for 4 mm² conductor cross section)
|
Nominal voltage UN
|
250 V
|
Open side panel
|
Yes
|
Shock protection test specification
|
DIN EN 50274 (VDE 0660-514):2002-11
|
Back of the hand protection
|
guaranteed
|
Finger protection
|
guaranteed
|
Result of surge voltage test
|
Test passed
|
Note
|
Only the crimping pliers “CRIMPFOX 6“ are approved for crimping with 6 mm² stranded and ferrule.
|
Result of power-frequency withstand voltage test
|
Test passed
|
Power frequency withstand voltage setpoint
|
1.5 kV
|
Result of the test for mechanical stability of terminal points (5 x conductor connection)
|
Test passed
|
Result of flexion and pull-out test
|
Test passed
|
Bending test rotation speed
|
10 rpm
|
Bending test turns
|
135
|
Bending test conductor cross section/weight
|
0.14 mm² / 0.2 kg
|
|
1.5 mm² / 0.4 kg
|
|
0.2 mm² / 0.2 kg
|
|
4 mm² / 0.9 kg
|
|
6 mm² / 1.4 kg
|
Tensile test result
|
Test passed
|
Result of tight fit on support
|
Test passed
|
Tight fit on carrier
|
NS 35
|
Setpoint
|
1 N
|
Result of voltage-drop test
|
Test passed
|
Result of temperature-rise test
|
Test passed
|
Requirement temperature-rise test
|
Increase in temperature ≤ 45 K
|
Short circuit stability result
|
Test passed
|
Conductor cross section short circuit testing
|
1.5 mm²
|
Short-time current
|
0.18 kA
|
Conductor cross section short circuit testing
|
2.5 mm²
|
Short-time current
|
0.3 kA
|
Conductor cross section short circuit testing
|
4 mm²
|
Short-time current
|
0.48 kA
|
Conductor cross section short circuit testing
|
6 mm²
|
Short-time current
|
0.72 kA
|
Result of thermal test
|
Test passed
|
Proof of thermal characteristics (needle flame) effective duration
|
30 s
|
Result of aging test
|
Test passed
|
Ageing test for screwless modular terminal block temperature cycles
|
192
|
Oscillation, broadband noise test result
|
Test passed
|
Test specification, oscillation, broadband noise
|
DIN EN 50155 (VDE 0115-200):2008-03
|
Test spectrum
|
Service life test category 2, bogie-mounted
|
Test frequency
|
f1 = 5 Hz to f2 = 250 Hz
|
ASD level
|
6.12 (m/s²)²/Hz
|
Acceleration
|
3.12g
|
Test duration per axis
|
5 h
|
Test directions
|
X-, Y- and Z-axis
|
Shock test result
|
Test passed
|
Test specification, shock test
|
DIN EN 50155 (VDE 0115-200):2008-03
|
Shock form
|
Half-sine
|
Acceleration
|
30g
|
Shock duration
|
18 ms
|
Number of shocks per direction
|
3
|
Test directions
|
X-, Y- and Z-axis (pos. and neg.)
|
Relative insulation material temperature index (Elec., UL 746 B)
|
130 °C
|
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
|
125 °C
|
Static insulating material application in cold
|
-60 °C
|
Surface flammability NFPA 130 (ASTM E 162)
|
passed
|
Specific optical density of smoke NFPA 130 (ASTM E 662)
|
passed
|
Calorimetric heat release NFPA 130 (ASTM E 1354)
|
27,5 MJ/kg
|
Smoke gas toxicity NFPA 130 (SMP 800C)
|
passed
|
Fire protection for rail vehicles (DIN EN 45545-2) R22
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R23
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R24
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R26
|
HL 1 - HL 3
|
Dimensions
Width
|
8.3 mm
|
Length
|
64 mm
|
Height NS 35/7,5
|
55.5 mm
|
Height NS 35/15
|
63 mm
|
Connection data
Connection method
|
Push-in connection
|
Stripping length
|
8 mm ... 10 mm
|
Connection in acc. with standard
|
IEC 60947-7-1
|
Conductor cross section solid min.
|
0.14 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
26
|
Conductor cross section AWG max.
|
14
|
Conductor cross section flexible min.
|
0.14 mm²
|
Conductor cross section flexible max.
|
1.5 mm²
|
Min. AWG conductor cross section, flexible
|
26
|
Max. AWG conductor cross section, flexible
|
14
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
1.5 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
1.5 mm²
|
Connection cross sections directly pluggable
|
0.34 mm² 2.5 mm² 20 14
|
Conductor cross section solid min.
|
0.34 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
20
|
Conductor cross section AWG max.
|
14
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.34 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
1.5 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.34 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
1.5 mm²
|
Note
|
Only the “CRIMPFOX 6” crimping pliers may be used for crimping with 6 mm² stranded and ferrule.
|
Connection
|
Feed-in stage
|
Stripping length
|
10 mm ... 12 mm
|
Connection in acc. with standard
|
IEC 60947-7-1
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
6 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
10
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
6 mm²
|
Min. AWG conductor cross section, flexible
|
24
|
Max. AWG conductor cross section, flexible
|
10
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.2 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
6 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.2 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
6 mm²
|
Connection cross sections directly pluggable
|
0.34 mm² 6 mm² 24 10
|
Conductor cross section solid min.
|
0.34 mm²
|
Conductor cross section solid max.
|
6 mm²
|
Value
|
0.34 mm²
|
|
6 mm²
|
|
0.34 mm²
|
|
6 mm²
|
Ambient conditions
Operating temperature
|
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
|
Ambient temperature (storage/transport)
|
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
|
Permissible humidity (storage/transport)
|
30 % ... 70 %
|
Ambient temperature (assembly)
|
-5 °C ... 70 °C
|
Ambient temperature (actuation)
|
-5 °C ... 70 °C
|
Standards and Regulations
Connection in acc. with standard
|
IEC 60947-7-1
|
|
IEC 60947-7-1
|
Flammability rating according to UL 94
|
V0
|
Environmental Product Compliance
China RoHS
|
Environmentally friendly use period: unlimited = EFUP-e
|
|
No hazardous substances above threshold values
|
ECLASS
ECLASS 10.0.1 |
27141120
|
ECLASS 11.0 |
27141120
|
ECLASS 5.1 |
27141141
|
ECLASS 6.0 |
27141100
|
ECLASS 7.0 |
27141120
|
ECLASS 9.0 |
27141120
|
ETIM
ETIM 6.0 |
EC000897
|
ETIM 7.0 |
EC000897
|
UNSPSC
UNSPSC 13.2 |
39121410
|
UNSPSC 18.0 |
39121410
|
UNSPSC 19.0 |
39121410
|
UNSPSC 20.0 |
39121410
|
UNSPSC 21.0 |
39121410
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|