Image is illustrative
|
Industrial Ethernet Switch FL SWITCH 2005, Phoenix Code:
2702323
Price (indicative)
Manufacturer
:
|
Availability:
21 days
|
Weight:
0.231 kg/pc
|
Volume:
0.0007 m3/pc
|
|
|
|
|
Industrial Ethernet Switch FL SWITCH 2005, PhoenixNote
|
Utilization restriction
|
EMC: class A product, see manufacturer's declaration in the download area
|
Dimensions
|
Width
|
45 mm
|
|
Height
|
130 mm
|
|
Depth
|
115 mm
|
Ambient conditions
|
Degree of protection
|
IP20
|
|
Ambient temperature (operation)
|
0 °C ... 60 °C
|
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
|
Permissible humidity (operation)
|
10 % ... 95 % (non-condensing)
|
|
Permissible humidity (storage/transport)
|
10 % ... 95 % (non-condensing)
|
|
Air pressure (operation)
|
86 kPa ... 108 kPa (1500 m above sea level)
|
|
Air pressure (storage/transport)
|
86 kPa ... 108 kPa (1500 m above sea level)
|
|
Degree of pollution
|
2
|
Interfaces
|
Interface
|
Ethernet (RJ45)
|
|
No. of ports
|
5 (RJ45 ports)
|
|
Note on the connection method
|
Auto negotiation and autocrossing
|
|
Transmission physics
|
Copper
|
|
Transmission speed
|
10/100 Mbps
|
|
Transmission length
|
100 m (per segment)
|
|
Signal LEDs
|
Data receive, link status
|
Function
|
Basic functions
|
Store-and-forward switch, complies with IEEE 802.3
|
|
Configuration memory
|
max. 8 GByte (SD card)
|
|
Management
|
Web-based management (HTTP/HTTPS)
|
|
|
Role-based user management
|
|
|
SNMPv1/v2/v3
|
|
|
Command-line interface (Telnet, SSH)
|
|
Diagnostic functions
|
RMON History
|
|
|
LLDP (Link Layer Discovery Protocol)
|
|
|
SNMP-Traps
|
|
|
N:1-Portmirroring
|
|
|
ACD (Address Conflict Detection)
|
|
|
SysLog
|
|
|
CRC-Surveillance
|
|
Filter functions
|
Quality of Service (8 priority classes)
|
|
|
Class of Service
|
|
|
DiffServ/DSCP
|
|
|
Port-Priorisierung
|
|
|
VLAN (up to 8 VLANs)
|
|
|
IGMP Snooping/Querier (v1/v2)
|
|
|
Auto-Query-Port
|
|
|
Extended Multicast Filtering
|
|
Redundancy
|
MRP (Media Redundancy Protocol)
|
|
|
RSTP (Rapid Spanning Tree Protocol)
|
|
Additional functions
|
Transmission of MMS and GOOSE (IEC 61850-8-1)
|
|
|
Transmission of Modbus TCP
|
|
MAC address table
|
8k
|
|
Latency
|
≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)
|
|
IP parameterization
|
DHCP-Client
|
|
|
DHCP server (port based)
|
|
|
BootP
|
|
PROFINET conformance class
|
Conformance-Class A
|
|
Time synchronization
|
SNTP (Simple Network Time Protocol)
|
|
Status and diagnostic indicators
|
LEDs: US (power supply), 2 LEDs per Ethernet port (Link/Activity and Speed)
|
Network expansion parameters
|
Cascading depth
|
Network, linear, and star structure: any
|
|
Maximum conductor length (twisted pair)
|
100 m
|
Supply voltage
|
Supply voltage
|
24 V DC (single)
|
|
Residual ripple
|
3.6 VPP (within the permitted voltage range)
|
|
Supply voltage range
|
18 V DC ... 32 V DC
|
|
Typical current consumption
|
165 mA (at US = 24 V DC and 25 °C ambient temperature)
|
|
Max. current consumption
|
0.3 A (At US = 18 V DC and 60°C ambient temperature)
|
|
Current consumption
|
165 mA
|
General
|
Mounting type
|
DIN rail
|
|
Type AX
|
Book type
|
|
Net weight
|
365 g
|
|
Housing material
|
Polycarbonate fiber reinforced
|
|
Note
|
Support by phone or on-site (fee is charged)
|
|
Latency
|
≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size)
|
|
MTTF
|
507.8 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
|
|
|
246.55 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
|
|
|
56.66 Years (SN 29500 standard, temperature 55°C, operating cycle 100%)
|
Connection data
|
Connection method
|
Push-in spring connection
|
|
Conductor cross section solid min.
|
0.25 mm²
|
|
Conductor cross section solid max.
|
1.5 mm²
|
|
Conductor cross section flexible min.
|
0.25 mm²
|
|
Conductor cross section flexible max.
|
1.5 mm²
|
|
Conductor cross section AWG min.
|
24
|
|
Conductor cross section AWG max.
|
16
|
|
Stripping length
|
9 mm
|
Standards and Regulations
|
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
|
Interference emission
|
EN 61000-6-2 EN 61000-6-4 (interference) Class A
|
|
Conducted noise emission
|
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
|
|
Immunity to surge
|
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
|
|
Immunity to burst
|
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
|
|
Immunity to EF
|
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
|
|
Immunity to ESD
|
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
|
|
Immunity to conducted interference
|
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
|
|
Type of test
|
Free fall in accordance with EN 61131-2
|
|
Noise emission
|
EN 61000-6-4
|
|
Noise immunity
|
EN 61000-6-2
|
|
Vibration (storage/transport)
|
2g, criterion 1 according to IEC 60068-2-6
|
|
Free from substances that could impair the application of coating
|
Yes
|
|
Vibration (operation)
|
2g, according to IEC 60068-2-6
|
|
Shock (operation)
|
30g (EN 60068-2-27)
|
|
UL, USA
|
UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1
|
|
UL, Canada
|
CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010-1-12, Ed.3
|
Environmental Product Compliance
|
REACh SVHC
|
Lead 7439-92-1
|
|
China RoHS
|
Environmentally Friendly Use Period = 50 years
|
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
| ECLASS 10.0.1 |
19170401
|
| ECLASS 11.0 |
19170401
|
| ECLASS 4.0 |
27250501
|
| ECLASS 4.1 |
27250501
|
| ECLASS 5.0 |
19030100
|
| ECLASS 5.1 |
19030100
|
| ECLASS 6.0 |
19170100
|
| ECLASS 7.0 |
19170106
|
| ECLASS 9.0 |
19170106
|
ETIM
| ETIM 3.0 |
EC000734
|
| ETIM 4.0 |
EC000734
|
| ETIM 6.0 |
EC000734
|
| ETIM 7.0 |
EC000734
|
UNSPSC
| UNSPSC 6.01 |
43172015
|
| UNSPSC 7.0901 |
43201404
|
| UNSPSC 11 |
43172015
|
| UNSPSC 12.01 |
43201410
|
| UNSPSC 13.2 |
43222612
|
| UNSPSC 18.0 |
43222612
|
| UNSPSC 19.0 |
43222612
|
| UNSPSC 20.0 |
43222612
|
| UNSPSC 21.0 |
43222612
|
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|
|