Elit logo e-Elit - leading
electronic and automation component
online distributor
Est En
Elit shopping basket
Items: Total:
0
€0.00
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
ISO Cylinder DSNU-25-100-PPV-A, 19248
ISO Cylinder DSNU-25-100-PPV-A, 19248



Potentiometer M22-R10K, ø22.5mm, 10kΩ 0.5W, front mount, IP66, Eaton
Image is illustrative
Potentiometer M22-R10K, ø22.5mm, 10kΩ 0.5W, front mount, IP66, Eaton
Code: 229491
Price
€26.10  /pc
Manufacturer :
Availability:
7 days
Weight:
0.0357 kg/pc
Volume:
0.0001 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Potentiometer M22-R10K, ø22.5mm, 10kΩ 0.5W, front mount, IP66, Eaton

Delivery program
RMQ design Classical
Part group reference (e.g. DIL) M22
Mounting hole diameter mm 22.5
Basic function Potentiometer
Single unit/Complete unit Single unit
Description 3 individual screw terminals
Accuracy of resistance value: ± 10% (linear)
Contact sequence
Impedance R kΩ 10
Rated power P W 0.5
Degree of Protection IP66
Front ring Bezel: titanium
Connection to SmartWire-DT no
For use with DILET…
ETR4-70
Technical data
General
Standards IEC/EN 60947
VDE 0660
Lifespan, mechanical Operations 25000
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Degree of Protection IP66
Ambient temperature
Open °C -25 - +70
Mounting position As required
Mechanical shock resistance g 30
Shock duration 11 ms
Sinusoidal
according to IEC 60068-2-27
Terminal capacities mm2
Solid mm2 0.5 - 1.5
Stranded mm2 0.5 - 1.5
Tightening torque for terminal screw Nm 0.5
Contacts
Rated impulse withstand voltage Uimp V AC 4000
Rated insulation voltage Ui V 250
Overvoltage category/pollution degree III/3
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
Rated operational current for specified heat dissipation In A 0
Heat dissipation per pole, current-dependent Pvid W 0
Equipment heat dissipation, current-dependent Pvid W 0
Static heat dissipation, non-current-dependent Pvs W 0.5
Heat dissipation capacity Pdiss W 0
Operating ambient temperature min. °C -25
Operating ambient temperature max. °C 70
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Please enquire
10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Potentiometer for control circuit devices (EC001027)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Potentiometer for command devices (ecl@ss8.1-27-37-12-27 [AKF045011])
Resistance Ohm 10000
Power consumption W 0.5
Hole diameter mm 22
Degree of protection (IP) IP66
Approvals
Product Standards IEC/EN 60947-5-1; UL 508; CSA-22.2 No. 14-05; CE marking
UL File No. E29184
UL Category Control No. NKCR
CSA File No. 012528
CSA Class No. 3211-03
North America Certification UL listed, CSA certified
Degree of Protection IEC: IP 66; UL/CSA Type: 3R, 4X, 12, 13
 
 