				Image is illustrative
			 | Analog Input Module FlexI/O, 8-ch., 24VDC, TS35/ panel mount Code:
		1794-IE8H
Price (indicative) 
				Manufacturer
			: 
| Availability:
			 21 days | Weight:  0.308 kg/pc | Volume:  0.0025 m3/pc |  |  |  |  |  
| 
| 
| Analog Input Module Flex I/O, 8-ch., 24VDC, TS35?panel mount, Allen-Bradley
DESCRIPTIONS
Flex™ I/O Analog Input Module, Type: Series B, Number Of Channels: 8 (Single-Ended, Non-Isolated), Voltage Rating: 19.2 - 31.2 VDC, Functional Data Range: More Than 17 V At 22 MA, More Than 23 V At 0 MA, Isolation: 50 V (Continuous), Basic Insulation Type, Routine Tested At 850 VDC For 1 SEC, Between Field Side And System, No Isolation Between Individual Channels, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2500 MHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2500 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 10 KHZ - 80 MHZ, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.95 IN, Height: 1.8 IN, Temperature Rating: -4 To 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 2 G At 10 - 500 HZ, Shock - Operating: 15 G, Non-Operating: 15 G, Accuracy: Absolute Accuracy: 0.1% Full Scale At 20 DEG C, Accuracy Drift With Temperature: 0.05% Full Scale For 0 - 55 DEG C, Power Dissipation: 3.9 W At 31.2 VDC, Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth (CM) On Power Ports, Plus/Minus 2 KV Line-Earth (CM) On Shielded Ports, Resolution: 16 Bits, Indicator: 8 Red Fault Indicator, 8 Yellow Channel Indicator, 1 Green Power, Bus Rating: Flexbus Current External Input: 5 VDC 80 MA, 24 VDC 190 MA, Keyswitch Position: 3, Input Step Response: Step Response To 99% - Current Terminal: 80 MS, Standard/Approvals: C/US UL listed, CE-ATEX, CE-EMC, C-tick, GOST_R, KCC certified, marine-BVS, ROSTECHNADZOR, RUS_PAT_APPR, Application: For in-cabinetsSPECIFICATIONS
Item Name: Analog Input Module
Type: Series B
Sub Brand: Flex™ I/O
Number Of Channels: 8 (Single-Ended, Non-Isolated)
Voltage Rating: 19.2 - 31.2 VDC, Functional Data Range: More Than 17 V At 22 MA, More Than 23 V At 0 MA
Isolation: 50 V (Continuous), Basic Insulation Type, Routine Tested At 850 VDC For 1 SEC, Between Field Side And System, No Isolation Between Individual Channels
Enclosure: Open Type
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2500 MHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2500 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 10 KHZ - 80 MHZ
Mounting: DIN Rail, Panel
Length: 3.7 IN
Width: 2.95 IN
Height: 1.8 IN
Temperature Rating: -4 To 131 DEG F
Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 2 G At 10 - 500 HZ, Shock - Operating: 15 G, Non-Operating: 15 G
Accuracy: Absolute Accuracy: 0.1% Full Scale At 20 DEG C, Accuracy Drift With Temperature: 0.05% Full Scale For 0 - 55 DEG C
Power Dissipation: 3.9 W At 31.2 VDC
Indicator: 8 Red Fault Indicator, 8 Yellow Channel Indicator, 1 Green Power
Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth (CM) On Power Ports, Plus/Minus 2 KV Line-Earth (CM) On Shielded Ports
Resolution: 16 Bits
Keyswitch Position: 3
Bus Rating: Flexbus Current External Input: 5 VDC 80 MA, 24 VDC 190 MA
Input Step Response: Step Response To 99% - Current Terminal: 80 MSFEATURES
FLEX I/O offers all the functions of larger rack-based I/O without the space requirements. Its cost effectiveness, flexibility, modularity, and reliability. FLEX I/O helps eliminate multiple long wiring runs, reduces terminations per point, decreases engineering and installation costs and time, and substantially reduces downtime. It complements all processor platforms. Can communicate on EtherNet/IP, ControlNet, DeviceNet, and PROFIBUS DP. Independently select the I/O, termination style, and network to meet your application needs. Conformally coated, extreme environment FLEX I/O products help to reduce panel costs and the need for additional heating/cooling equipment, resulting in lower installation and maintenance costs. Reduced space - wire direct from sensor to terminal base and eliminate terminal stripFunctionality: 4- through 32-point modules offer functions of larger rack-based I/OIncreased productivity: easy configuration and setup of I/O modules using wizards speeds engineering and installationReduced downtime: removal and insertion under power (RIUP) and diagnosticsOperation in harsh environments: conformal coated and extreme environment rated modulesNetwork flexibility: communicates on EtherNet/IP, ControlNet, DeviceNet, and PROFIBUS DPImproved plant operations: HART analog modules pass through HART data to asset management software or controller for improved plant operationsStandards: C/US UL listed, CE-ATEX, CE-EMC, C-tick, GOST_R, KCC certified, marine-BVS, ROSTECHNADZOR, RUS_PAT_APPRApplications: For in-cabinets
 |  
| 
| File description | File type | Download link |  
|  |  |  |  | "
			Spec Sheet | .pdf | Download link |  
|  |  |  |  |  |  |  
  |