Elit logo e-Elit - leading
electronic and automation component
online distributor
Est En
Elit shopping basket
Items: Total:
0
€0.00
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Inner Door EUPI, 800Wx1800H, double bar locking w. 3mm double-bit insert, incl. vert. uprights, hori. rails, mount accessories, C3M| epoxy resin layer, ETA, grey
Inner Door EUPI, 800Wx1800H, double bar locking w. 3mm double-bit insert, incl. vert. uprights, hori. rails, mount accessories, C3M| epoxy resin layer, ETA, grey



Digital DC I/O Module CompactLogix, 8-ch., 24VDC, 145mA 5.1V drawn, TS35, panel mount, Allen-Bradley
Image is illustrative
Digital DC I/O Module CompactLogix, 8-ch., 24VDC, 145mA 5.1V drawn, TS35, panel mount, Allen-Bradley
Code: 1769-OB8
Price (indicative)
€245.40  /pc
Manufacturer :
Availability:
21 days
Weight:
0.287 kg/pc
Volume:
0.001 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Digital DC I/O Module CompactLogix, 8-ch., 24VDC, 145mA 5.1V drawn, TS35 ?panel mount, Allen-Bradley

DESCRIPTIONS
CompactLogix™ Digital DC I/O Module, Number Of Channels: 8 (4 Points/Group), Output: Operating Voltage: 20.4 - 26.4 VDC, Off-State Leakage Current: 1 MA At 26.4 VDC (Maximum), On-State Current: 1 MA (Minimum), On-State Voltage Drop: 1 VDC At 2 A (Maximum), Voltage Rating: 24 VDC, Current Rating: Drawn: 145 MA At 5.1 V, Current Per Point: 2 A At 60 DEG C (Maximum), Current Per Module: 8 A At 60 DEG C (Maximum), Isolation: 1200 VAC For 1 SEC Or 1697 VDC For 1 SEC, Output Point To Bus, And Group To Group, 75 VDC Working Voltage, Enclosure: Open Type, Display: Status LED, Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded, Mounting: DIN Rail, Panel, Length: 1.38 IN, Width: 3.43 IN, Height: 4.65 IN, Temperature Rating: 32 - 140 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G At 10 - 500 HZ (Operating), 2 G (Relay Operating), Shock - Panel Mount: 30 G (Operating), 7.5 G (Relay Operating), 40 G (Non-Operating), DIN Rail Mount: 20 G (Operating), 5 G (Relay Operating), 30 G (Non-Operating), Response Time: Delay (On): 0.1 MS, Delay (Off): 1 MS At 60 DEG C Maximum Load 2 A, Min V In 20.4 V, 1.5 MS At 60 DEG C Maximum Load 1 MA, Min V In 20.4 V, Power Dissipation: 2.20 W, Output Type: Current Sourcing, Slot Width: 1, Surge Current: 4 A For 10 MS, Repeatable Every 2 SEC, Standard/Approvals: C/US UL listed, UL 508 listed, CSA C22.2, file number 142, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
SPECIFICATIONS
  • Item Name: Digital DC I/O Module

  • Sub Brand: CompactLogix™

  • Number Of Channels: 8 (4 Points/Group)

  • Output: Operating Voltage: 20.4 - 26.4 VDC, Off-State Leakage Current: 1 MA At 26.4 VDC (Maximum), On-State Current: 1 MA (Minimum), On-State Voltage Drop: 1 VDC At 2 A (Maximum)

  • Voltage Rating: 24 VDC

  • Current Rating: Drawn: 145 MA At 5.1 V, Current Per Point: 2 A At 60 DEG C (Maximum), Current Per Module: 8 A At 60 DEG C (Maximum)

  • Isolation: 1200 VAC For 1 SEC Or 1697 VDC For 1 SEC, Output Point To Bus, And Group To Group, 75 VDC Working Voltage

  • Enclosure: Open Type

  • Display: Status LED

  • Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded

  • Mounting: DIN Rail, Panel

  • Length: 1.38 IN

  • Width: 3.43 IN

  • Height: 4.65 IN

  • Temperature Rating: 32 - 140 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G At 10 - 500 HZ (Operating), 2 G (Relay Operating), Shock - Panel Mount: 30 G (Operating), 7.5 G (Relay Operating), 40 G (Non-Operating), DIN Rail Mount: 20 G (Operating), 5 G (Relay Operating), 30 G (Non-Operating)

  • Response Time: Delay (On): 0.1 MS, Delay (Off): 1 MS At 60 DEG C Maximum Load 2 A, Min V In 20.4 V, 1.5 MS At 60 DEG C Maximum Load 1 MA, Min V In 20.4 V

  • Power Dissipation: 2.20 W

  • Output Type: Current Sourcing

  • Surge Current: 4 A For 10 MS, Repeatable Every 2 SEC

  • Slot Width: 1

FEATURES

Most output modules have built-in surge suppression to reduce the effects of high-voltage transients. Use an additional suppression device if an output is being used to control inductive devices, such as relays, motor starters, solenoids, or motors. Additional suppression is especially important if your inductive device is in series with or parallel to hard contacts, such as push buttons or selector switches. Add a suppression device directly across the coil of an inductive device to reduce the effects of voltage transients caused by interrupting the current to that device and to prolong the life of the switch contacts.

  • Logic circuits determine the output status
  • An output LED indicates the status of the output signal
  • Optical isolation separates module logic and bus circuits from field power
  • The output driver turns the corresponding output on or off
  • Standards: C/US UL listed, UL 508 listed, CSA C22.2, file number 142, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
 
 