|
|
Image is illustrative
|
Digital Output Module ControlLogix, 8-ch., w. diagnostics, electronic protection, output 165mA 18..32VDC, TS35, Allen-Bradley Code:
1715-OB8DE
Price (indicative)
Manufacturer
:
Availability:
ask for dd
|
Weight:
0.3045 kg/pc
|
Volume:
0.0009 m3/pc
|
|
|
|
|
Digital Output Module ControlLogix, 8-ch., w. diagnostics ˄electronic protection, output 165mA 18..32VDC, TS35, Allen-Bradley
DESCRIPTIONS
ControlLogix® Digital Output Module With Diagnostics And Electronic Protection, Number Of Channels: 8, Output: Operating Voltage Range - Backplane: 165 MA At 18 - 32 VDC, Nominal: 24 VDC, Pilot Duty Rating: 16 VA, 1.5 Inrush, Current Rating: On-State Output Current: 1 A Continuous For Each Point, Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC, Power Rating: Less Than 2 W, Enclosure: Open Type, Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Display: Module Health And Status, Connection Cables: 18 - 16 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 1-5/8 IN, Width: 4-5/8 IN, Height: 6-1/2 IN, Temperature Rating: -13 To 158 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock Operating - Din Rail Mount: 25 G, Panel Mount: 30 G, Shock Non-Operating - Installed: 30 G, Uninstalled: 50 G, Power Dissipation: System: 3 W, Field Loop: 0.17 W, Output Type: Current Sourcing, Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports, Standard/Approvals: C/US UL listed, CE certified, C-Tick certified, GOST_R certified, KCC certified, ROSTECHNADZOR
SPECIFICATIONS
-
Item Name: Digital Output Module With Diagnostics And Electronic Protection
-
Sub Brand: ControlLogix®
-
Number Of Channels: 8
-
Output: Operating Voltage Range - Backplane: 165 MA At 18 - 32 VDC, Nominal: 24 VDC, Pilot Duty Rating: 16 VA, 1.5 Inrush
-
Current Rating: On-State Output Current: 1 A Continuous For Each Point
-
Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC
-
Power Rating: Less Than 2 W
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Display: Module Health And Status
-
Connection Cables: 18 - 16 AWG Solid/Stranded Copper Wire
-
Mounting: DIN Rail
-
Length: 1-5/8 IN
-
Width: 4-5/8 IN
-
Height: 6-1/2 IN
-
Temperature Rating: -13 To 158 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock Operating - Din Rail Mount: 25 G, Panel Mount: 30 G, Shock Non-Operating - Installed: 30 G, Uninstalled: 50 G
-
Power Dissipation: System: 3 W, Field Loop: 0.17 W
-
Output Type: Current Sourcing
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports
FEATURES
Each I/O module is an isolated module that plugs into a single position of the I/O base unit and a termination assembly that is mounted to the base unit. - Standards: C/US UL listed, CE certified, C-Tick certified, GOST_R certified, KCC certified, ROSTECHNADZOR
|
|
File description
|
File type
|
Download link
|
|
|
|
Specification Sheet
|
PDF
|
Download link
|
|
|
|
|