e-Elit - juhtiv
elektri- ja automaatikatarvikute
online hulgimüük
Klienditeenindus E-R 9-17
Helista: +372 622 9119
Est En
Elit shopping basket
Tooteid: Maksumus:
0
€ 0,00
    search
Logi sisse
Kasutajatunnus/e-post:

Parool:

Näita kõiki kategooriaid
Ei leidnud sobilikku toodet?
Head pakkumised!
ISO Cylinder DNC-80-1300-PPV-A, 163432
ISO Cylinder DNC-80-1300-PPV-A, 163432



Simatic S7-1200, Communication Module CM 1241, RS232, 9pole D-sub (pin), supports Freeport
Pilt on illustreeriv
Simatic S7-1200, Communication Module CM 1241, RS232, 9pole D-sub (pin), supports Freeport
Kood: 6ES7241-1AH32-0XB0
Hind (indikatiivne)
€ 95,00  /tk
Tootja :
Saadavus:
21 päeva
Kaal:
0.1638 kg/tk
Maht:
0.0005 m3/tk
Kogus (tk):
Plus sign Minus sign
 

 

Simatic S7-1200, Communication Module CM 1241, RS232, 9pole D-sub (pin), supports Freeport, Siemens

SIMATIC S7-1200, Communication module CM 1241, RS232, 9-pole D-sub (pin), supports Freeport
General information
Product type designation CM 1241 RS 232
Supply voltage
Rated value (DC)
● 24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Input current
Current consumption, max. 200 mA; From backplane bus 5 V DC
Power loss
Power loss, typ. 1.1 W
Interfaces
Number of interfaces 1
Interface physics, RS 232C (V.24) Yes
Point-to-point connection
● Cable length, max. 10 m
Integrated protocol driver
— Freeport Yes
— ASCII Yes; Available as library function
— Modbus Yes
— Modbus RTU master Yes
— MODBUS RTU slave Yes
Protocols
Integrated protocols
Freeport
— Telegram length, max. 1 kbyte
— Bits per character 7 or 8
— Number of stop bits 1 (Standard), 2
— Parity No parity (standard); even, uneven, mark (parity bit always 1); space (parity bit always 0)
3964 (R)
— Telegram length, max. 1 kbyte
— Bits per character 7 or 8
— Number of stop bits 1 (Standard), 2
— Parity No parity (standard); even, uneven, mark (parity bit always 1); space (parity bit always 0)
Modbus RTU master
— Address area 1 through 49 999 (Standard Modbus addressing)
— Number of slaves, max. 247; slave numbers 1 through 247, per MODBUS network segment maximum 32 devices, additional repeaters needed to expand the network to maximum configuration
MODBUS RTU slave
— Address area 1 through 49 999 (Standard Modbus addressing)
Interrupts/diagnostics/status information
Diagnostics function Yes
Diagnostics indication LED
● for status of the outputs Yes
Degree and class of protection
Degree of protection acc. to EN 60529
● IP20 Yes
Standards, approvals, certificates
CE mark Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Ambient conditions
Free fall
● Fall height, max. 0.3 m; five times, in product package
Ambient temperature during operation
● min. -20 °C
● max. 60 °C
● horizontal installation, min. -20 °C
● horizontal installation, max. 60 °C
● vertical installation, min. -20 °C
● vertical installation, max. 50 °C
● permissible temperature change 5°C to 55°C, 3°C / minute
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Air pressure acc. to IEC 60068-2-13
● Operation, min. 795 hPa
● Operation, max. 1 080 hPa
● Storage/transport, min. 660 hPa
● Storage/transport, max. 1 080 hPa
Relative humidity
● Operation at 25 ℃ without condensation, max. 95 %
Dimensions
Width 30 mm
Height 100 mm
Depth 75 mm
Weights
Weight, approx. 150 g
last modified: 11/10/2018
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2021 ©


 