Compact Analog I/O Module CompactLogix, 6-ch., 120mA 5.1VDC drawn, Rockwell Automation
Compact Analog I/O Module CompactLogix, 6-ch., 120mA 5.1VDC drawn, Rockwell Automation



Liigpingepiirik, 3P+N, T1+T2, Uc 320VAC, impulse current (10/350μs) Iimp 12.5kA/(N-PE)50kA, discharge current (8/20μs)| Imax 60kA, In 25kA/(N-PE)50kA, abikontakt, TT/TNS, Legrand
Pilt on illustreeriv
Liigpingepiirik, 3P+N, T1+T2, Uc 320VAC, impulse current (10/350μs) Iimp 12.5kA/(N-PE)50kA, discharge current (8/20μs)| Imax 60kA, In 25kA/(N-PE)50kA, abikontakt, TT/TNS, Legrand
Kood: 412277
Hind
€ 218,55  /tk
Tootja :
Saadavus:
28 päeva
Kaal:
0.6307 kg/tk
Maht:
0.0009 m3/tk
Kogus (tk):
Plus sign Minus sign
 

 

Surge Arrester, 3P+N, FS, T1+T2, Uc 320VAC, impulse current (10/350μs) Iimp 12.5kA/(N-PE)50kA, discharge current (8/20μs)| Imax 60kA, In 25kA/(N-PE)50kA, TT/TNS, Legrand

Product charateristics
  • T1+T2
Recommendation / Restriction
  • "To provide correct protection, a lightning arrester is recommended: - at the origin of each installation (mandatory depending on the type and location of the installation to be protected, - at the origin of divisional switchboards: secondary protection or fine protection of sensitive equipment, - on all outputs of external electrical circuits (supply to secondary buildings, external lighting or external electrical panels, etc.). A communication network arrester should always be installed to protect communication equipment in the presence of a lightning arrester on the low-voltage network."

Technical characteristics

System configuration IT No
System configuration TN Yes
System configuration TN-C No
System configuration TN-C-S No
System configuration TN-S No
System configuration TT Yes
System configuration other No
Number of conductors (without earthing) 4
Nominal discharge surge current In (8/20) 25 kA
Nominal voltage AC 400 V
Max. continuous voltage AC 320 V
Voltage protection level L-N 2.2 kV
Voltage protection level N-PE 1.5 kV
Integrated backup fuse No
Mounting method DIN rail (top hat rail) 35 mm
Construction size 4 modular spacing
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
With remote signalling contact Yes
Signalling at the device Optical
Category type 2 Yes
Degree of protection (IP) IP20