|
|
Pilt on illustreeriv
|
Distribution Block PTFIX 6/6X2.5 RD, 10pcs/pck, Phoenix Kood:
3273334
Hind
€ 42,00
/pk
Package 10tk, unit price
4.2EUR/tk
Tootja
:
Saadavus:
21 päeva
|
Kaal:
0.02 kg/tk
|
Maht:
0.0001 m3/tk
|
|
|
|
|
Distribution Block PTFIX 6/6X2.5 RD, 10pcs/pck, PhoenixGeneral
Note
|
Notes on operation the blocks can be bridged with one another via the conductor shaft, for corresponding plug-in bridges, see accessories
|
Number of rows
|
1
|
Number of connections
|
7
|
Potentials
|
1
|
Nominal cross section
|
2.5 mm²
|
Nominal cross section feed-in
|
6 mm²
|
Color
|
red
|
Insulating material
|
PA
|
Flammability rating according to UL 94
|
V0
|
Mounting type
|
for snapping onto a DIN rail adapter
|
Rated surge voltage
|
6 kV
|
Degree of pollution
|
3
|
Overvoltage category
|
III
|
Insulating material group
|
I
|
Maximum load current
|
32 A (with 4 mm² conductor cross section)
|
Maximum total current
|
57 A (with 10 mm² conductor cross section)
|
Nominal current IN
|
24 A
|
Nominal voltage UN
|
450 V
|
Maximum load current
|
57 A (with 10 mm² conductor cross section)
|
Nominal current IN
|
41 A (with 6 mm² conductor cross section)
|
Open side panel
|
No
|
Result of tight fit on support
|
Test passed
|
Tight fit on carrier
|
NS 35/NS 15
|
Note
|
When aligning several blocks, it is recommended to either place a DIN rail adapter underneath the connection point or a flange element between the blocks.
|
|
For versions with 6 or 7 connections, it is sufficient to place one DIN rail adapter in the middle of each block and to use flange elements after every second block. Depending on the application case and mechanical load, other arrangements of the mounting accessory can also be chosen.
|
|
When using the DIN rail adapter PTFIX-NS35, an ligned block must not protrude by more than a half.
|
Result of thermal test
|
Test passed
|
Proof of thermal characteristics (needle flame) effective duration
|
30 s
|
Oscillation, broadband noise test result
|
Test passed
|
Test specification, oscillation, broadband noise
|
DIN EN 50155 (VDE 0115-200):2008-03
|
Test spectrum
|
Service life test category 2, bogie-mounted
|
Test frequency
|
f1 = 5 Hz to f2 = 250 Hz
|
ASD level
|
6.12 (m/s²)²/Hz
|
Acceleration
|
3.12g
|
Test duration per axis
|
5 h
|
Test directions
|
X-, Y- and Z-axis
|
Shock test result
|
Test passed
|
Test specification, shock test
|
DIN EN 50155 (VDE 0115-200):2008-03
|
Shock form
|
Half-sine
|
Acceleration
|
30g
|
Shock duration
|
18 ms
|
Number of shocks per direction
|
3
|
Test directions
|
X-, Y- and Z-axis (pos. and neg.)
|
Relative insulation material temperature index (Elec., UL 746 B)
|
125 °C
|
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
|
125 °C
|
Static insulating material application in cold
|
-60 °C
|
Dimensions
Width
|
25.6 mm
|
Length
|
28.6 mm
|
Height
|
21.7 mm
|
Connection data
Connection method
|
Push-in connection
|
Stripping length
|
8 mm ... 10 mm
|
Connection in acc. with standard
|
IEC 60998-2-2
|
Conductor cross section solid min.
|
0.14 mm²
|
Conductor cross section solid max.
|
4 mm²
|
Conductor cross section AWG min.
|
26
|
Conductor cross section AWG max.
|
12
|
Conductor cross section flexible min.
|
0.14 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Min. AWG conductor cross section, flexible
|
26
|
Max. AWG conductor cross section, flexible
|
14
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
2.5 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
2.5 mm²
|
Connection cross sections directly pluggable
|
0.34 mm² 4 mm² 24 12
|
Conductor cross section solid min.
|
0.34 mm²
|
Conductor cross section solid max.
|
4 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.34 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
2.5 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.34 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
2.5 mm²
|
Internal cylindrical gage
|
A3
|
Connection
|
Feed-in stage
|
Connection method
|
Push-in connection
|
Stripping length
|
10 mm ... 12 mm
|
Connection in acc. with standard
|
IEC 60998-2-2
|
Conductor cross section solid min.
|
0.5 mm²
|
Conductor cross section solid max.
|
10 mm²
|
Conductor cross section AWG min.
|
20
|
Conductor cross section AWG max.
|
8
|
Conductor cross section flexible min.
|
0.5 mm²
|
Conductor cross section flexible max.
|
10 mm²
|
Min. AWG conductor cross section, flexible
|
20
|
Max. AWG conductor cross section, flexible
|
10
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.5 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
6 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.5 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
6 mm²
|
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
|
0.5 mm²
|
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
|
1.5 mm²
|
Connection cross sections directly pluggable
|
1 mm² 10 mm²
|
Conductor cross section solid min.
|
1 mm²
|
Conductor cross section solid max.
|
10 mm²
|
Value
|
1 mm²
|
|
6 mm²
|
|
1 mm²
|
|
6 mm²
|
Ambient conditions
Operating temperature
|
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
|
Ambient temperature (storage/transport)
|
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
|
Permissible humidity (storage/transport)
|
30 % ... 70 %
|
Ambient temperature (assembly)
|
-5 °C ... 70 °C
|
Ambient temperature (actuation)
|
-5 °C ... 70 °C
|
Standards and Regulations
Connection in acc. with standard
|
IEC 60998-2-2
|
|
IEC 60998-2-2
|
Flammability rating according to UL 94
|
V0
|
Environmental Product Compliance
China RoHS
|
Environmentally friendly use period: unlimited = EFUP-e
|
|
No hazardous substances above threshold values
|
ECLASS
ECLASS 10.0.1 |
27141120
|
ECLASS 11.0 |
27141120
|
ECLASS 4.0 |
27141121
|
ECLASS 4.1 |
27141121
|
ECLASS 5.0 |
27141120
|
ECLASS 5.1 |
27141120
|
ECLASS 6.0 |
27141100
|
ECLASS 7.0 |
27141120
|
ECLASS 9.0 |
27141120
|
ETIM
ETIM 3.0 |
EC000897
|
ETIM 4.0 |
EC000897
|
ETIM 6.0 |
EC000897
|
ETIM 7.0 |
EC000897
|
UNSPSC
UNSPSC 6.01 |
30211811
|
UNSPSC 7.0901 |
39121410
|
UNSPSC 11 |
39121410
|
UNSPSC 12.01 |
39121410
|
UNSPSC 13.2 |
39121410
|
UNSPSC 18.0 |
39121410
|
UNSPSC 19.0 |
39121410
|
UNSPSC 20.0 |
39121410
|
UNSPSC 21.0 |
39121410
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|