Pilt on illustreeriv
|
Fuse Modular Terminal Block UT 4-HESILED 24 (5x20), 50pcs/pck, Phoenix Kood:
3046090
Hind
€ 595,00
/pk
Package 50tk, unit price
11.9EUR/tk
Tootja
:
Saadavus:
21 päeva
|
Kaal:
0.0172 kg/tk
|
Maht:
0 m3/tk
|
|
|
|
|
Fuse Modular Terminal Block UT 4-HESILED 24 (5x20), 50pcs/pck, PhoenixGeneral
Note
|
The current is determined by the fuse used, the voltage by the selected LED. If the fuse is faulty, the downstream circuit will not be disconnected.
|
Number of rows
|
1
|
Number of connections
|
2
|
Nominal cross section
|
4 mm²
|
Color
|
black
|
Insulating material
|
PA
|
Flammability rating according to UL 94
|
V0
|
Area of application
|
Railway industry
|
|
Machine building
|
|
Plant engineering
|
Rated surge voltage
|
6 kV
|
Degree of pollution
|
3
|
Overvoltage category
|
III
|
Insulating material group
|
I
|
Maximum power dissipation
|
max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
|
|
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
|
|
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
|
|
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
|
LED voltage range
|
12 V AC/DC ... 30 V AC/DC
|
LED current range
|
0.31 mA ... 0.95 mA
|
Connection in acc. with standard
|
IEC 60947-7-3
|
Maximum load current
|
6.3 A (the current is determined by the fuse used)
|
Nominal current IN
|
6.3 A
|
Nominal voltage UN
|
24 V
|
Fuse
|
G / 5 x 20
|
Fuse type
|
Glass / ceramics / ...
|
Open side panel
|
No
|
Relative insulation material temperature index (Elec., UL 746 B)
|
130 °C
|
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
|
125 °C
|
Static insulating material application in cold
|
-60 °C
|
Surface flammability NFPA 130 (ASTM E 162)
|
passed
|
Specific optical density of smoke NFPA 130 (ASTM E 662)
|
passed
|
Smoke gas toxicity NFPA 130 (SMP 800C)
|
passed
|
Calorimetric heat release NFPA 130 (ASTM E 1354)
|
27,5 MJ/kg
|
Fire protection for rail vehicles (DIN EN 45545-2) R22
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R23
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R24
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R26
|
HL 1 - HL 3
|
Dimensions
Width
|
6.2 mm
|
Length
|
57.8 mm
|
Height NS 35/7,5
|
73 mm
|
Height NS 35/15
|
80.5 mm
|
Connection data
Conductor cross section solid min.
|
0.14 mm²
|
Conductor cross section solid max.
|
6 mm²
|
Conductor cross section flexible min.
|
0.14 mm²
|
Conductor cross section flexible max.
|
6 mm²
|
Conductor cross section AWG min.
|
26
|
Conductor cross section AWG max.
|
10
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
4 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
4 mm²
|
2 conductors with same cross section, solid min.
|
0.14 mm²
|
2 conductors with same cross section, solid max.
|
1.5 mm²
|
2 conductors with same cross section, stranded min.
|
0.14 mm²
|
2 conductors with same cross section, stranded max.
|
1.5 mm²
|
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
|
0.14 mm²
|
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
|
1.5 mm²
|
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
|
0.5 mm²
|
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
|
2.5 mm²
|
Connection method
|
Screw connection
|
Stripping length
|
9 mm
|
Internal cylindrical gage
|
A4
|
Screw thread
|
M3
|
Tightening torque, min
|
0.6 Nm
|
Tightening torque max
|
0.8 Nm
|
Ambient conditions
Operating temperature
|
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
|
Ambient temperature (storage/transport)
|
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
|
Permissible humidity (storage/transport)
|
30 % ... 70 %
|
Ambient temperature (assembly)
|
-5 °C ... 70 °C
|
Ambient temperature (actuation)
|
-5 °C ... 70 °C
|
Standards and Regulations
Connection in acc. with standard
|
CSA
|
|
IEC 60947-7-3
|
Flammability rating according to UL 94
|
V0
|
Environmental Product Compliance
China RoHS
|
Environmentally Friendly Use Period = 50 years
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27141116
|
ECLASS 11.0 |
27141116
|
ECLASS 4.0 |
27141100
|
ECLASS 4.1 |
27141100
|
ECLASS 5.0 |
27141100
|
ECLASS 5.1 |
27141100
|
ECLASS 6.0 |
27141100
|
ECLASS 7.0 |
27141116
|
ECLASS 9.0 |
27141116
|
ETIM
ETIM 2.0 |
EC000897
|
ETIM 3.0 |
EC000899
|
ETIM 4.0 |
EC000899
|
ETIM 6.0 |
EC000899
|
ETIM 7.0 |
EC000899
|
UNSPSC
UNSPSC 6.01 |
30211811
|
UNSPSC 7.0901 |
39121410
|
UNSPSC 11 |
39121410
|
UNSPSC 12.01 |
39121410
|
UNSPSC 13.2 |
39121410
|
UNSPSC 18.0 |
39121410
|
UNSPSC 19.0 |
39121410
|
UNSPSC 20.0 |
39121410
|
UNSPSC 21.0 |
39121410
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|