Adapter, läbiviiguplaat ECOR kilbile, ava FL13, 135x55 | multiläbiviigule MB/HTB, perforeeritud, kompl. paigaldustarvikud, ETA, hall
Adapter, läbiviiguplaat ECOR kilbile, ava FL13, 135x55 | multiläbiviigule MB/HTB, perforeeritud, kompl. paigaldustarvikud, ETA, hall



DC/DC Converter QUINT-PS/48DC/48DC/5, 1pcs/pck, Phoenix
Pilt on illustreeriv
DC/DC Converter QUINT-PS/48DC/48DC/5, 1pcs/pck, Phoenix
Kood: 2905008
Hind
€ 510,50  /tk
Tootja :
Saadavus:
21 päeva
Kaal:
1.1072 kg/tk
Maht:
0.0027 m3/tk
Kogus (tk):
Plus sign Minus sign
 

 

DC/DC Converter QUINT-PS/48DC/48DC/5, 1pcs/pck, Phoenix

Dimensions

Width 48 mm
Height 130 mm
Depth 125 mm
Width with alternative assembly 122 mm
Height with alternative assembly 130 mm
Depth with alternative assembly 51 mm
Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2

Input data

Nominal input voltage range 48 V DC
Input voltage range 30 V DC ... 60 V DC
Current consumption 7 A (48 V, IBOOST)
Inrush current < 6 A (typical)
Mains buffering time typ. 10 ms (48 V DC)
Input fuse 15 A (internal (device protection))
Type of protection Transient surge protection
Protective circuit/component Varistor

Output data

Nominal output voltage 48 V DC ±1 %
Setting range of the output voltage (USet) 30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
Nominal output current (IN) 5 A (-25 °C ... 60 °C)
POWER BOOST (IBoost) 6.25 A (-25 °C ... 40 °C permanent, UOUT = 48 V DC )
Selective Fuse Breaking (ISFB) 30 A (12 ms)
Derating 60 °C ... 70 °C (2.5%/K)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Feedback voltage resistance 60 V DC
Protection against overvoltage at the output (OVP) < 60 V DC
Max. capacitive load unlimited
Active current limitation 7 A
Control deviation < 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 20 mVPP
Peak switching voltages nominal load < 10 mVPP (20 MHz)
Maximum power dissipation in no-load condition 2.7 W
Power loss nominal load max. 20 W

General

Net weight 0.9 kg
Efficiency > 93 %
MTBF (IEC 61709, SN 29500)
> 872000 h (40 °C)
Insulation voltage input/output 1.5 kV (type test)
1 kV (routine test)
Degree of protection IP20
Protection class III
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection data, input

Connection method Pluggable screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 8 mm
Screw thread M3

Connection data, output

Connection method Pluggable screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M3

Connection data for signaling

Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M3

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage EN 60950-1 (SELV)
EN 60204 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Rail applications EN 50121-4

Conformance/approvals

UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Electrostatic discharge EN 61000-4-2
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 1 GHz ... 2 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 2 GHz ... 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Surge voltage load (surge) EN 61000-4-5
Input 1 kV (Test Level 3 - asymmetrical)
2 kV (Test Level 3 - asymmetrical)
Output 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion A
Conducted interference EN 61000-4-6
I/O/S asymmetrical
Frequency range 0.1 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

Environmental Product Compliance

REACh SVHC Lead 7439-92-1

ECLASS

ECLASS 10.0.1 27210901
ECLASS 11.0 27210901
ECLASS 4.0 27210900
ECLASS 4.1 27210900
ECLASS 5.0 27210900
ECLASS 5.1 27210900
ECLASS 6.0 27210900
ECLASS 7.0 27210901
ECLASS 9.0 27210901

ETIM

ETIM 6.0 EC002046
ETIM 7.0 EC002046

UNSPSC

UNSPSC 13.2 39121041
UNSPSC 18.0 39121041
UNSPSC 19.0 39121041
UNSPSC 20.0 39121041
UNSPSC 21.0 39121041
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2021 ©


 
X
 
X