				Pilt on illustreeriv
			 
 
 | 
Coupling Relay PSR-PC20-1NO-1NC-24DC-SC, 1pcs/pck, Phoenix Kood:
		2700577
 
 
Hind (indikatiivne) 
				Tootja
			: 
| 
 Saadavus:
			 
21 päeva 
 | 
 Kaal:  
0.1986 kg/tk 
 | 
 Maht:  
0.0004 m3/tk 
 | 
 | 
 
 
 | 
 | 
 
 
 | 
 
Coupling Relay PSR-PC20-1NO-1NC-24DC-SC, 1pcs/pck, PhoenixNote
| 
Utilization restriction
 | 
EMC: class A product, see manufacturer's declaration in the download area
 | 
 
| 
 | 
Use in potentially explosive areas is not permitted in China.
 | 
 
 Dimensions
| 
Width
 | 
12.5 mm
 | 
 
| 
Height
 | 
112.2 mm
 | 
 
| 
Depth
 | 
114.5 mm
 | 
 
 Ambient conditions
| 
Ambient temperature (operation)
 | 
-40 °C ... 70 °C (observe derating)
 | 
 
| 
Ambient temperature (storage/transport)
 | 
-40 °C ... 85 °C
 | 
 
| 
Max. permissible relative humidity (operation)
 | 
75 % (on average, 85% infrequently, non-condensing)
 | 
 
| 
Max. permissible humidity (storage/transport)
 | 
75 % (on average, 85% infrequently, non-condensing)
 | 
 
| 
Maximum altitude
 | 
≤ 2000 m (Above sea level)
 | 
 
 Power supply
| 
Rated control circuit supply voltage US
 | 
24 V DC -15 % / +10 % (A1/A2)
 | 
 
| 
 | 
20.4 V DC ... 26.4 V DC
 | 
 
| 
Rated control supply current IS
 | 
typ. 50 mA
 | 
 
| 
Input voltage range "0" signal
 | 
0 V DC ... 5 V DC (for safe Off)
 | 
 
| 
Input current range "0" signal
 | 
0 mA ... 2 mA (for safe Off)
 | 
 
| 
Power consumption at US
 | 
typ. 1.2 W
 | 
 
| 
Inrush current
 | 
typ. 400 mA (Δt < 10 µs at Us)
 | 
 
| 
Filter time
 | 
max. 2 ms (at A1-A2; test pulse width)
 | 
 
| 
 | 
≥ 100 ms (at A1-A2; test pulse rate)
 | 
 
| 
Diagnostic supply voltage UD
 | 
24 V DC -15 % / +10 % (31/A2, TBUS)
 | 
 
| 
Input current at UD
 | 
6 mA (at 31-A2 for UD; depending on load + 100 mA at M1 and 32)
 | 
 
| 
Inrush current at UD
 | 
typ. 2.5 A (Δt < 20 µs at UD)
 | 
 
| 
Protective circuit
 | 
Serial protection against polarity reversal 33 V suppressor diode (A1/A2)33 V suppressor diode (31/A2)
 | 
 
 Relay outputs: enabling current path
| 
Output name
 | 
Enabling current path
 | 
 
| 
Output description
 | 
2 N/O contacts in series, without delay, floating
 | 
 
| 
Number of outputs
 | 
1 (safety-related N/O contacts: 13/14 (13F/14))
 | 
 
| 
Contact type
 | 
1 enabling current path
 | 
 
| 
Contact material
 | 
AgSnO2
 | 
 
| 
Switching voltage
 | 
min. 12 V AC/DC
 | 
 
| 
 | 
max. 250 V AC/DC (Observe the load curve)
 | 
 
| 
Limiting continuous current
 | 
6 A (13/14 for high-demand)
 | 
 
| 
 | 
4 A (13F/14 with high/low demand, 13/14 with low demand)
 | 
 
| 
Inrush current
 | 
min. 3 mA
 | 
 
| 
 | 
max. 6 A (N/O contact 13/14)
 | 
 
| 
 | 
4 A (N/O contact 13F/14)
 | 
 
| 
Sq. Total current
 | 
36 A2 (13/14, see to derating)
 | 
 
| 
 | 
16 A2 (13F/14, see to derating)
 | 
 
| 
Switching capacity
 | 
min. 60 mW
 | 
 
| 
Switching frequency
 | 
max. 0.5 Hz
 | 
 
| 
Mechanical service life
 | 
10x 106 cycles
 | 
 
| 
Switching capacity according to IEC 60947-5-1
 | 
4 A (24 V (DC13); N/O contact 13/14)
 | 
 
| 
 | 
5 A (250 V (AC15); N/O contact 13/14)
 | 
 
| 
 | 
4 A (250 V (AC15); N/O contact 13F/14)
 | 
 
| 
Output fuse
 | 
6 A gL/gG (N/O contact 13/14)
 | 
 
| 
 | 
4 A gL/gG (for low-demand applications)
 | 
 
 Relay outputs: return current/signaling current path
| 
Output name
 | 
Confirmation current path
 | 
 
| 
Output description
 | 
2 N/C contacts in series, without delay, not floating (reference ground: A2)
 | 
 
| 
Number of outputs
 | 
1 (safety-related N/C contacts: 31/32)
 | 
 
| 
Contact type
 | 
1 confirmation current path
 | 
 
| 
Contact material
 | 
AgCuNi, + Au
 | 
 
| 
Switching voltage
 | 
min. 20.4 V DC
 | 
 
| 
 | 
max. 26.4 V DC
 | 
 
| 
Limiting continuous current
 | 
100 mA
 | 
 
| 
Inrush current
 | 
min. 1 mA
 | 
 
| 
 | 
max. 100 mA
 | 
 
| 
Switching capacity
 | 
min. 20 mW
 | 
 
| 
Switching frequency
 | 
max. 0.5 Hz
 | 
 
| 
Mechanical service life
 | 
10x 106 cycles
 | 
 
| 
Output fuse
 | 
150 mA Fast-blow
 | 
 
 Alarm outputs
| 
Designation
 | 
M1
 | 
 
| 
Output description
 | 
PNP
 | 
 
| 
Number of outputs
 | 
1 (non-safety-related)
 | 
 
| 
Voltage
 | 
approx. 22 V DC (UD - 2 V)
 | 
 
| 
Current
 | 
max. 100 mA
 | 
 
| 
Maximum inrush current
 | 
500 mA (Δt = 1 ms at Us)
 | 
 
| 
Short-circuit protection
 | 
no
 | 
 
| 
Output fuse
 | 
150 mA fast blow
 | 
 
 Times
| 
Typical pickup time at US
 | 
< 100 ms (with Us when controlled via A1)
 | 
 
| 
Typical release time at US
 | 
< 35 ms (when controlled via A1)
 | 
 
| 
Recovery time
 | 
500 ms
 | 
 
 General
| 
Relay type
 | 
Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
 | 
 
| 
Nominal operating mode
 | 
100% operating factor
 | 
 
| 
Net weight
 | 
189.1 g
 | 
 
| 
Mounting position
 | 
vertical, horizontal, with front of module upward
 | 
 
| 
Mounting type
 | 
DIN rail mounting
 | 
 
| 
Assembly instructions
 | 
See derating curve
 | 
 
| 
Degree of protection
 | 
IP20
 | 
 
| 
Min. degree of protection of inst. location
 | 
IP54
 | 
 
| 
Housing material
 | 
Polyamide
 | 
 
| 
Housing color
 | 
yellow
 | 
 
| 
Operating voltage display
 | 
1 x yellow LED
 | 
 
| 
Status display
 | 
1 x green LED
 | 
 
| 
Indication
 | 
1 x red LED
 | 
 
 Connection data
| 
Connection method
 | 
Screw connection
 | 
 
| 
pluggable
 | 
Yes
 | 
 
| 
Conductor cross section solid
 | 
0.2 mm² ... 2.5 mm²
 | 
 
| 
Conductor cross section flexible
 | 
0.2 mm² ... 2.5 mm²
 | 
 
| 
Conductor cross-section AWG
 | 
24 ... 12
 | 
 
| 
Stripping length
 | 
7 mm
 | 
 
| 
Screw thread
 | 
M3
 | 
 
| 
Torque
 | 
0.5 Nm ... 0.6 Nm
 | 
 
 Safety-related characteristic data
| 
Stop category in accordance with IEC 60204
 | 
0
 | 
 
| 
Designation
 | 
IEC 61508 - High demand
 | 
 
| 
Safety Integrity Level (SIL)
 | 
3
 | 
 
| 
Designation
 | 
IEC 61508 - Low demand
 | 
 
| 
Safety Integrity Level (SIL)
 | 
3
 | 
 
| 
Designation
 | 
EN 50156
 | 
 
| 
Safety Integrity Level (SIL)
 | 
3
 | 
 
 Standards and Regulations
| 
Designation
 | 
Air clearances and creepage distances between the power circuits
 | 
 
| 
Standards/regulations
 | 
DIN EN 50178, EN 60079-15
 | 
 
| 
Rated insulation voltage
 | 
250 V AC
 | 
 
| 
Rated surge voltage/insulation
 | 
Safe isolation, 6 kV reinforced insulation from control circuit, start circuit, confirmation current path, signal output to the enabling current path; 4 kV/basic insulation between all current paths and housing
 | 
 
| 
Degree of pollution
 | 
2
 | 
 
| 
Overvoltage category
 | 
III
 | 
 
| 
Shock
 | 
15g
 | 
 
| 
Vibration (operation)
 | 
10 Hz ... 150 Hz, 2g
 | 
 
| 
Conformance
 | 
CE-compliant
 | 
 
| 
ATEX
 | 
 II 3 G Ex nA nC IIC T4 Gc
 | 
 
| 
IECEx
 | 
Ex nA nC IIC T4 Gc
 | 
 
| 
UL, USA/Canada
 | 
cULus
 | 
 
| 
 | 
Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X
 | 
 
| 
 | 
Class I, Div. 2, Groups A, B, C, D, T4
 | 
 
| 
GL
 | 
C, EMC2
 | 
 
| 
Environmental simulation test
 | 
ISA-S71.04 (G3)
 | 
 
 Environmental Product Compliance
| 
REACh SVHC
 | 
Lead 7439-92-1
 | 
 
| 
China RoHS
 | 
Environmentally Friendly Use Period = 50 years
 | 
 
| 
 | 
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
 | 
 
 ECLASS
| ECLASS 10.0.1 | 
27371819
 | 
 
| ECLASS 11.0 | 
27371819
 | 
 
| ECLASS 4.0 | 
40020600
 | 
 
| ECLASS 4.1 | 
40020600
 | 
 
| ECLASS 5.0 | 
27371900
 | 
 
| ECLASS 5.1 | 
27371900
 | 
 
| ECLASS 6.0 | 
27371800
 | 
 
| ECLASS 7.0 | 
27371819
 | 
 
| ECLASS 9.0 | 
27371819
 | 
 
 ETIM
| ETIM 6.0 | 
EC001449
 | 
 
| ETIM 7.0 | 
EC001449
 | 
 
 UNSPSC
| UNSPSC 18.0 | 
39122205
 | 
 
| UNSPSC 19.0 | 
39122205
 | 
 
| UNSPSC 20.0 | 
39122205
 | 
 
| UNSPSC 21.0 | 
39122205
 | 
 
 
 | 
 
 
| 
File description
 | 