Analog Current Input Module CompactLogix, 16-ch. 16bits, Rockwell Automation Kood:
1769-IF16C
Hind (indikatiivne)
Tootja
:
Saadavus:
küsi tarneaega
|
Kaal:
0.272 kg/tk
|
Maht:
0.001 m3/tk
|
|
|
|
|
Analog Current Input Module CompactLogix, 16-ch. 16bits, Rockwell Automation
DESCRIPTIONS
Compact I/O™ Analog Input Module, Number Of Channels: 16, Input: 0 - 20 MA, 4 - 20 MA, 30 VAC/VDC, Current Rating: Drawn: 70 MA At 24 V, Isolation: 500 VAC Or 710 VDC For 1 MIN (Qualification Test), Output Group To Bus, Enclosure: Open Type, Display: Status LED, Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded, Mounting: DIN Rail, Panel, Length: 87 MM, Width: 35 MM, Height: 118 MM, Temperature Rating: 0 - 60 DEG C, Environmental Conditions: Relative Humidity: 5 - 95%Noncondensing, Vibration: 2 G, Shock: 30 G, Accuracy: Plus Or minus 0.5 % Full Scale, Power Dissipation: 4 W, Impedance: 249 OHM, Resolution: 16 Bits Unipolar, 15 Bits Plus Sign Bipolar, Rejection Ratio: Common Mode: Greater Than 60 DB, Slot Width: 1, Standard/Approvals: GOST_R certified, KCC certified, ROSTECHNADZOR, RUS_PAT approved
|
|
SPECIFICATIONS
- Item Name: Analog Input Module
- Sub Brand: Compact I/O™
- Number Of Channels: 16
- Input: 0 - 20 MA, 4 - 20 MA, 30 VAC/VDC
- Current Rating: Drawn: 70 MA At 24 V
- Isolation: 500 VAC Or 710 VDC For 1 MIN (Qualification Test), Output Group To Bus
- Enclosure: Open Type
- Display: Status LED
- Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded
- Mounting: DIN Rail, Panel
- Length: 87 MM
- Width: 35 MM
- Height: 118 MM
- Temperature Rating: 0 - 60 DEG C
- Environmental Conditions: Relative Humidity: 5 - 95%Noncondensing, Vibration: 2 G, Shock: 30 G
- Accuracy: Plus Or minus 0.5 % Full Scale
- Power Dissipation: 4 W
- Resolution: 16 Bits Unipolar, 15 Bits Plus Sign Bipolar
- Impedance: 249 OHM
- Rejection Ratio: Common Mode: Greater Than 60 DB
- Slot Width: 1
FEATURES
Bulletin 1769 Compact I/O™ modules can be used as local and distributed I/O for a CompactLogix™, Compact GuardLogix®, or MicroLogix™ 1500 controller. Rack-type features in a rackless design lower costs and reduce replacement parts inventory. A built-in removable terminal block provides connections to I/O sensors and actuators.
Sigma delta input conversion
22 input word
2 output word
98 configuration words
Provide individually configurable channels
Bulletin 1769 Compact I/O™ modules can be used as local and distributed I/O for a CompactLogix™, Compact GuardLogix®, or MicroLogix™ 1500 controller
Standards: GOST_R certified, KCC certified, ROSTECHNADZOR, RUS_PAT approved
|
|
|
|