e-Elit - juhtiv
elektri- ja automaatikatarvikute
online hulgimüük
Klienditeenindus E-R 9-17
Helista: +372 622 9119
Est En
Elit shopping basket
Tooteid: Maksumus:
0
€ 0,00
    search
Logi sisse
Kasutajatunnus/e-post:

Parool:

Näita kõiki kategooriaid
Ei leidnud sobilikku toodet?
Head pakkumised!



Digital DC Output Module ControlLogix, 16-ch., 12/24VDC, 210mA 5.1V drawn, Allen-Bradley
Pilt on illustreeriv
Digital DC Output Module ControlLogix, 16-ch., 12/24VDC, 210mA 5.1V drawn, Allen-Bradley
Kood: 1756-OV16E
Hind (indikatiivne)
€ 314,30  /tk
Tootja :
Saadavus:
21 päeva
Kaal:
0.382 kg/tk
Maht:
0.002 m3/tk
Kogus (tk):
Plus sign Minus sign
 

 

Digital DC Output Module ControlLogix, 16-ch., 12/24VDC, 210mA 5.1V drawn, Allen-Bradley

DESCRIPTIONS
ControlLogix® Digital DC Output Module, Number Of Channels: 16, Output: Operating Voltage: 10 - 30 VDC, On-State Voltage Drop: 700 M VDC At 1 A, Voltage Rating: 12/24 VDC, Current Rating: Drawn: 210 MA At 5.1 V, 2 MA At 24 V, Off-State Leakage Current Per Point: 1 MA Per Point, Current Per Point: 1 A At 60 DEG C, Current Per Module: 8 A At 60 DEG C, Load Current: 2 MA Per Point, Isolation: 250 V (Continuous), Basic Insulation Type, Outputs-To-Backplane, And Output Group-To-Group, No Isolation Between Individual Group Outputs, 1350 VAC For 2 SEC Routine Test, Power Rating: Backplane: 1.12 W, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Display: Output, Fault And Communication Status, Module Health, Interface: Removable Terminal Block, Mounting: Chassis, Width: 1-3/8 IN, Height: 5-23/32 IN, Temperature Rating: 32 - 140 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 30 G(Operating), 50 G (Non-Operating), Response Time: Delay (Off To On): 75 MIC-SEC Nominal/1 MS Maximum, Delay (On To Off): 360 MIC-SEC Nominal/1 MS Maximum, Power Dissipation: 6.72 W At 60 DEG C, Output Type: Current Sinking, Slot Width: 1, Surge Current: 2 A For 10 MS/Point, Repeatable Every 2 SEC At 60 DEG C, Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports, Standard/Approvals: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, CE-LVD, C-TICK, FM-US_HAZ, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-LR, ROSTECHNADZOR
SPECIFICATIONS
  • Item Name: Digital DC Output Module

  • Sub Brand: ControlLogix®

  • Number Of Channels: 16

  • Output: Operating Voltage: 10 - 30 VDC, On-State Voltage Drop: 700 M VDC At 1 A

  • Voltage Rating: 12/24 VDC

  • Current Rating: Drawn: 210 MA At 5.1 V, 2 MA At 24 V, Off-State Leakage Current Per Point: 1 MA Per Point, Current Per Point: 1 A At 60 DEG C, Current Per Module: 8 A At 60 DEG C, Load Current: 2 MA Per Point

  • Isolation: 250 V (Continuous), Basic Insulation Type, Outputs-To-Backplane, And Output Group-To-Group, No Isolation Between Individual Group Outputs, 1350 VAC For 2 SEC Routine Test

  • Power Rating: Backplane: 1.12 W

  • Enclosure: Open Type

  • Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ

  • Display: Output, Fault And Communication Status, Module Health

  • Interface: Removable Terminal Block

  • Mounting: Chassis

  • Width: 1-3/8 IN

  • Height: 5-23/32 IN

  • Temperature Rating: 32 - 140 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 30 G(Operating), 50 G (Non-Operating)

  • Response Time: Delay (Off To On): 75 MIC-SEC Nominal/1 MS Maximum, Delay (On To Off): 360 MIC-SEC Nominal/1 MS Maximum

  • Power Dissipation: 6.72 W At 60 DEG C

  • Output Type: Current Sinking

  • Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports

  • Surge Current: 2 A For 10 MS/Point, Repeatable Every 2 SEC At 60 DEG C

  • Slot Width: 1

FEATURES
  • Variety of voltage interface capabilities
  • Isolated and nonisolated module types
  • Point-level output fault states
  • Direct-connect or rack-optimized communication
  • Field-side diagnostics on select modules
  • These modules have internal electronic fusing to prevent too much current from flowing through the module
  • Standards: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, CE-LVD, C-TICK, FM-US_HAZ, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-LR, ROSTECHNADZOR
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2021 ©


 
X
 
X