|
|
Pilt on illustreeriv
|
Diagnostic Digital DC Input Module Point I/O, 4-ch., 10..28.8VDC, Allen-Bradley Kood:
1734-IB4D
Hind (indikatiivne)
Tootja
:
Saadavus:
21 päeva
|
Kaal:
0.0408 kg/tk
|
Maht:
0.0001 m3/tk
|
|
|
|
|
Diagnostic Digital DC Input Module Point I/O, 4-ch., 10..28.8VDC, Allen-Bradley
DESCRIPTIONS
-
Point I/O™ Digital DC Input Module, Type: Diagnostic, Number Of Channels: 4, Input: Field Power Bus - Supply Voltage: 24 VDC Nominal, Voltage Range: 10 - 28.8 VDC, On-State Voltage: 11 VDC (Minimum), On-State Voltage: 28.8 VDC (Maximum), On-State Current: 2 MA (Minimum), On-State Current: 15 MA (Maximum), Off-State Voltage: -3 VDC (Minimum), Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA (Minimum), Off to On Filter: 0 US, Off to On Filter: 65535 US, On to Off Filter: 0 US, Off to On Filter: 65535 US, Isolation: 50 VDC (Continuous), Reinforced Insulation Type Tested at 1000 VDC For 60 SEC, Field-Side To System, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100%AM At 1890 MHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 2.97 IN, Width: 0.47 IN, Height: 2.2 IN, Temperature Rating: -4 To 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Shock: 30 G (Operating), 50 G (Nonoperating), Vibration: 5 G, Power Dissipation: 0.6 W At 28.8 VDC, Output Type: Current Sinking, Keyswitch Position: 1, Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports, Bus Rating: 50 MA Maximum At 5 VDC, Standard/Approvals: C/US UL listed, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, ROSTECHNADZOR, Application: For in-cabinets
SPECIFICATIONS
-
-
Item Name: Digital DC Input Module
-
Type: Diagnostic
-
Sub Brand: Point I/O™
-
Number Of Channels: 4
-
Input: Field Power Bus - Supply Voltage: 24 VDC Nominal, Voltage Range: 10 - 28.8 VDC, On-State Voltage: 11 VDC (Minimum), On-State Voltage: 28.8 VDC (Maximum), On-State Current: 2 MA (Minimum), On-State Current: 15 MA (Maximum), Off-State Voltage: -3 VDC (Minimum), Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA (Minimum), Off to On Filter: 0 US, Off to On Filter: 65535 US, On to Off Filter: 0 US, Off to On Filter: 65535 US
-
Isolation: 50 VDC (Continuous), Reinforced Insulation Type Tested at 1000 VDC For 60 SEC, Field-Side To System
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100%AM At 1890 MHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire
-
Mounting: DIN Rail
-
Length: 2.97 IN
-
Width: 0.47 IN
-
Height: 2.2 IN
-
Temperature Rating: -4 To 131 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Shock: 30 G (Operating), 50 G (Nonoperating), Vibration: 5 G
-
Power Dissipation: 0.6 W At 28.8 VDC
-
Output Type: Current Sinking
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports
-
Keyswitch Position: 1
-
Bus Rating: 50 MA Maximum At 5 VDC
FEATURES
-
- Input module with short-circuit and open-wire diagnostics
- Standards: C/US UL listed, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, ROSTECHNADZOR
- Applications: For in-cabinets
|
|
|
|